Description / Abstract:
Introduction
Note: Nothing in this standard supercedes
applicable laws and regulations.
Note: In the event of conflict between the
English and domestic language, the English language shall take
precedence.
Purpose. The purpose of the relay is to switch
and carry load currents while a minor control current through the
relay coil is applied.
The relay shall provide only two (2) operating modes:
- Switching Contact Open: No current flows
- Switching Contact Closed: Load current flows An intermediate
stage is not permitted.
Applicability. This standard applies to the
following relays which are defined as follows:
- Relay with Normally Closed (NC) contacts: Single Pole Single
Throw (SPST), NC
- Relay with Normally Open (NO) contacts: SPST, NO
- Relay with changeover contacts: Single Pole Double Throw
(SPDT)
- Relay with multiple contacts: Double Pole Double Throw
(DPDT)
- Solid State Relay (SSR): Constructed with electronic components
which switch the load current on and off by means of Field Effect
Transistors (FET) or electromechanical relays
- Multiple coil
- Latching
Remarks. This specification covers the testing
of general purpose electromechanical plug-in, Printed Circuit Board
(PCB), and SSRs. It presents a series of physical, environmental
and durability tests, and product requirements which are used to
determine the capability of a relay as specified by the part
drawing.
Where a user's engineering practices or needs are not applicable
to all features of this standard, it is intended that as many
details as is practical be followed.