Liquid Cooling Guidelines for Datacom Equipment Centers

Liquid Cooling Guidelines for Datacom Equipment Centers

ASHRAE Technical Committee 9.9, Mission Critical Facilities, Technology Spaces, and Electronic Equipment ASHRAE / 2006 / 100 pages ISBN: 9781933742052

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$25.37 tax incl.

$59.00 tax incl.

(price reduced by 57 %)

1000 items in stock

Data center IT equipment today is predominantly air cooled. However, with rack heat loads steadily climbing, the ability for many data centers to deliver either adequate airflow rates or sufficient chilled air is now being stretched to the limit. These trends in the heat load generated from IT equipment can have detrimental side effects, such as decresed equipment availability, wasted floor space, and inefficient cooling system operation. This situation is creating a need for implementing liquid cooling solutions. The overall goals of the liquid implementations include aspects such as trasferring as much waste heat to the facility liquid cooling loop as possible, reducing the overall volume of airflow needed by the racks, and reducing processor temperatures such that increased compute performance can be achieved.

This book on liquid cooling is divided into six chapters and includes definitions for liquid and air cooling as it applies to the IT equipment, describing the various liquid loops that can exist in a building that houses a data center. It also provides the reader an overview of the chilled-water and condenser water systems and an overview of datacom equipment cooling options. The book also bridges the liquid cooling systems by providing guidelines on the interface requirements between the chilled-water system and the technology cooling system and outlines the requirements of those liquid-cooled systems that attach to a datacom electronics rack and are implemented to aid in data center thermal management.

This book is the fourth in a series of datacom books published by ASHRAE and authored by TC 9.9, Mission Critical Facilities, Technology Spaces, and Electronic Equipment. The other books, listed in order of publication, are Thermal Guidelines for Data Processing Environments, Datacom Equipment Power Trends and Cooling Applications, and Design Considerations for Datacom Equipment Centers.

It is 6 x 9 in. in size and softcover. The book was printed on 30% post-consumer waste using soy-based inks.

Keywords: data, data centers, data center, data processing, datacom, data com, energy consumption measurements; energy efficiency

Liquid Cooling Guidelines for Datacom Equipment Centers is not an ASHRAE Guideline and has not been developed in accordance with ASHRAEs consensus process.

Citation: ASHRAE Book



Product Code(s): 90430,D-90430

This product is related to: Particulate and Gaseous Contamination in Datacom Environments
Green Tips for Data Centers
Thermal Guidelines for Data Processing Environments, 2nd Ed.
High Density Data Centers - Case Studies and Best Practices
Design Considerations for Datacom Equipment Centers, 2nd Ed.
Datacom Equipment Power Trends and Cooling Applications
Structural and Vibration Guidelines for Datacom Equipment Centers
Best Practices for Datacom Facility Energy Efficiency, 2nd Ed.

People Who Bought This Also Bought:
ASHRAE - Thermal Guidelines for Data Processing Environments, 2nd Ed.ASHRAE - Datacom Equipment Power Trends and Cooling ApplicationsASHRAE - Best Practices for Datacom Facility Energy Efficiency, 2nd Ed.ASHRAE - High Density Data Centers - Case Studies and Best PracticesASHRAE - Design Considerations for Datacom Equipment Centers, 2nd Ed.ASHRAE - Particulate and Gaseous Contamination in Datacom EnvironmentsASHRAE - Structural and Vibration Guidelines for Datacom Equipment CentersASHRAE - Real-Time Energy Consumption Measurements in Data CentersASHRAE - SL-08-018 -- Airflow and Cooling Performance of Data Centers: Two Performance MetricsASHRAE - Standard 90.1-2004 User's Manual
View Contents (PDF)

Contact us