ASHRAE 23.1-2010

ASHRAE 23.1-2010

Standard 23.1-2010 -- Methods of Testing for Rating the Performance of Positive Displacement Refrigerant Compressors and Condensing Units That Operate at Subcritical Temperatures (ANSI Approved) ASHRAE / 2010 / 12 pages

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$16.77 tax incl.

$39.00 tax incl.

(price reduced by 57 %)

1000 items in stock

This standard is a revision of ASHRAE Standard 23-2005. ASHRAE is in the process of developing a companion standard, Standard 23.2, that will address the testing of positive displacement compressors and condensers using refrigerants like CO2 that operate at supercritical temperatures.

This standard applies to the methods of testing for rating the thermodynamic performance of single-stage positive-displacement refrigerant compressors and condensing units that operate at subcritical temperatures of the refrigerant which either (a) do not have liquid injection or (b) incorporate liquid injection that is achieved by compressor motor power. This standard applies to all of the refrigerants listed in ASHRAE Standard 34,1 Designation and Safety Classification of Refrigerants, that fall within the scope defined in Section 2.1.

Standard 23.1 also clarifies some of the procedures of Standard 23-2005 and updates its references. Standard 23.1 retains all of the improvements that were made when the 2005 edition of Standard 23 was published. In addition to the azeotropic refrigerants that were the focus of the 1993 edition, it covers zeotropic alternative refrigerants as well. It provides the choice of six different test methods for determining refrigerant mass flow rates, and it allows the same test to be used for the primary and confirming tests-provided that the primary and confirming tests are simultaneous and completely independent. It includes test methods that properly account for the effects of liquid refrigerant injection within the scope of the standard, and it includes computations of compressor efficiencies that harmonize the standard with relevant standards promulgated by ARI, ISO, and other entities.

It is intended that, after Standards 23.1 and 23.2 have been published, ASHRAE Standard 23-2005 will be withdrawn.

Keywords: compressor testing, positive displacement compressors, compressor performance, compressors operating at subcritical temps



Product Code(s): 86051,D-86051

This product is related to: BV US Compliance Insider 2010:Electrical-Electronics - Standard 23.1-2010 -- Methods of Testing for Rating the Performance of Positive Displacement Refrigerant Compressors and Condensing Units That Operate at Subcritical Temperatures (ANSI Approved)
This product replaces:ANSI/ASHRAE 23-2005 - Standard 23-2005 -- Methods of Testing for Rating Positive Displacement Refrigerant Compressors and Condensing Units (ANSI approved)
Browse Product Family:

ASHRAE 23.1-2010
ANSI/ASHRAE 23-2005
ANSI/ASHRAE 23-1993

People Who Bought This Also Bought:
ANSI/ASHRAE 41.7-1984 (RA 2006)- Standard 41.7-1984 (RA 2006) -- Method of Test for Measurement of Flow of Gas (ANSI approved)ANSI/ASHRAE 41.10-2008- Standard 41.10-2008 -- Standard Methods for Volatile-Refrigerant Mass Flow Measurements Using Flowmeters (ANSI/ASHRAE Approved)ANSI/ASHRAE 15-2007 and 34-2007 SET- Standard 15-2007 (packaged w/ Standard 34-2007) -- Safety Standard for Refrigeration Systems (ANSI Approved) and Standard 34-2007 -- Designation and Classification of RefrigerantsASHRAE 41.9-2000 (RA 2006)- Standard 41.9-2000 (RA 2006) -- Calorimeter Test Methods for Mass Flow Measurements of Volatile Refrigerants (ANSI approved)ASHRAE 41.8-1989- Standard 41.8-1989 -- Standard Methods of Measurement of Flow of Liquids in Pipes Using Orifice Flowmeters
View Contents (PDF)

Contact us